Wc-3 Ultrasonic Interference

Aim

To demonstrate interference of two sound sources.

Apparatus

  • Three ultrasonic transducers
  • Signal generator
  • C.R.O

Ultrasonic Interference Diagram

Ultrasonic Interference Apparatus.

Description

Two ultrasonic transducers are connected to a signal generator set to their resonant frequency of 26kHz. A third transducer is connected to a C.R.O. and placed perpendicular to the line joining the transmitters. As the receiver is moved along this line, maxima and minima are displayed on the C.R.O.

Safety Notes

Ultrasonic Interference SOP-36